This series of heavy-duty truck charging stations includes 240/320/360/400/480KW dual-gun DC fast chargers, 360/480/720KW multi-output liquid-cooled DC charging clusters, 360/480/600/720/960KW multi-output intelligent flexible charging clusters, and 1.2/1.44/1.96/2.88MW heavy-duty truck megawatt superchargers. They come with multiple safety protections like high-temperature, over/under-voltage, and leakage protection, and support various start methods such as scanning a code, swiping a card, VIN code start, scheduled start, and offline start. They’re easy to use and help optimize management and scheduling.
Product Introduction
240/320/360/400/480KW dual-gun DC fast chargers
Technical Parameters
Rated Power | 240KW |
Number of Charging Guns | 2 |
Output Current | 250A per gun, 500A for dual guns |
Rated Input Voltage | 380VAC ±15%, 3-phase+N+PE |
Protection Functions | Safe isolation with AC contactor; overvoltage, undervoltage, overcurrent, short-circuit, earth fault, battery anti-reverse current, over-temperature protection for modules, cabinet over-temperature protection, charging cable over-temperature protection, insulation monitoring protection |
Cable & Circuit Breaker | Single cable: 3×185mm²+2×95mm²Residual current circuit breaker: 3P, 500A, 440V, 30mA |
Output Voltage Range | DC 200–1000V |
Startup Modes | QR code scan / VIN / Dual gun parallel charging / Plug-and-charge / Card swiping / Manual operation |
Charging Cable Length | 7 m |
Cooling Method | Intelligent air cooling for main cabinet |
Protection Class | IP54 |
Overall Dimensions | 1700*700*710 mm |
Operating Temperature | -25~ +55°C |
Rated Power | 320KW |
Number of Charging Guns | 2 |
Output Current | 250A per gun, 500A for dual guns |
Rated Input Voltage | 380VAC ±15%, 3-phase+N+PE |
Protection Functions | Safe isolation with AC contactor; overvoltage, undervoltage, overcurrent, short-circuit, earth fault, battery anti-reverse current, over-temperature protection for modules, cabinet over-temperature protection, charging cable over-temperature protection, insulation monitoring protection |
Cable & Circuit Breaker | Single cable: 3×240mm²+2×120mm²Residual current circuit breaker: 3P, 630A, 440V, 30mA |
Output Voltage Range | DC 200–1000V |
Startup Modes | QR code scan / VIN / Dual gun parallel charging / Plug-and-charge / Card swiping / Manual operation |
Charging Cable Length | 7 m |
Cooling Method | Intelligent air cooling for main cabinet |
Protection Class | IP54 |
Overall Dimensions | 1700*700*710 mm |
Operating Temperature | -25~ +55°C |
Rated Power | 360KW |
Number of Charging Guns | 2 |
Output Current | 250A per gun, 500A for dual guns |
Rated Input Voltage | 380VAC ±15%, 3-phase+N+PE |
Protection Functions | Safe isolation with AC contactor; overvoltage, undervoltage, overcurrent, short-circuit, earth fault, battery anti-reverse current, over-temperature protection for modules, cabinet over-temperature protection, charging cable over-temperature protection, insulation monitoring protection |
Cable & Circuit Breaker | Single cable: 3×300mm²+2×150mm²Residual current circuit breaker: 3P, 800A, 440V, 30mA |
Output Voltage Range | DC 200–1000V |
Startup Modes | QR code scan / VIN / Dual gun parallel charging / Plug-and-charge / Card swiping / Manual operation |
Charging Cable Length | 7 m |
Cooling Method | Intelligent air cooling for main cabinet |
Protection Class | IP54 |
Overall Dimensions | 1700*700*710 mm |
Operating Temperature | -25~ +55°C |
Rated Power | 400KW |
Number of Charging Guns | 2 |
Output Current | 300A per gun, 600A for dual guns |
Rated Input Voltage | 380VAC ±15%, 3-phase+N+PE |
Protection Functions | Safe isolation with AC contactor; overvoltage, undervoltage, overcurrent, short-circuit, earth fault, battery anti-reverse current, over-temperature protection for modules, cabinet over-temperature protection, charging cable over-temperature protection, insulation monitoring protection |
Cable & Circuit Breaker | Dual cable dual input: 2*3×185mm²+2×95mm²Residual current circuit breaker: 3P, 2*500A, 440V,30mA |
Output Voltage Range | DC 200–1000V |
Startup Modes | QR code scan / VIN / Dual gun parallel charging / Password charging / Card swiping / Manual operation |
Charging Cable Length | 7 m |
Cooling Method | Intelligent air cooling for main cabinet |
Protection Class | IP54 |
Overall Dimensions | 1700*800*710 mm |
Operating Temperature | -25~+55°C |
Rated Power | 480KW |
Number of Charging Guns | 2 |
Output Current | 300A per gun, 600A for dual guns |
Rated Input Voltage | 380VAC ±15%, 3-phase+N+PE |
Protection Functions | Safe isolation with AC contactor; overvoltage, undervoltage, overcurrent, short-circuit, earth fault, battery anti-reverse current, over-temperature protection for modules, cabinet over-temperature protection, charging cable over-temperature protection, insulation monitoring protection |
Cable & Circuit Breaker | Dual cable dual input: 2*3×185mm²+2×95mm²Residual current circuit breaker: 3P, 2*500A, 440V |
Output Voltage Range | DC 200–1000V |
Startup Modes | QR code scan / VIN / Dual gun parallel charging / Password charging / Card swiping / Manual operation |
Charging Cable Length | 7 m |
Cooling Method | Intelligent air cooling for main cabinet |
Protection Class | IP54 |
Overall Dimensions | 1700*800*710 mm |
Operating Temperature | -25~+55°C |